{"publisher":"Xirkit — the structured parts marketplace","canonical":"https://www.xirkit.io/products/brainco-revo-2-dexterous-hand-16a5","markdown":"https://www.xirkit.io/products/brainco-revo-2-dexterous-hand-16a5/data.md","mcp":"https://www.xirkit.io/mcp","note":"Every value is traced to a cited source (see sources and per-value src). Null means unknown, never zero.","record":{"id":"16a54794-3bc9-5b64-8803-80ca781a3e48","mpn":"Revo 2 Basic (XRL / XRR)","name":"BrainCo Revo 2 Dexterous Hand","manufacturer":"BrainCo","family":"end_effector","summary":"BrainCo Revo 2 is a 383 g, 160 mm bionic dexterous hand with 6 coreless motors driving 6 active joints and 11 DoF. It grips with ≥ 50 N (≥ 15 N pinch), holds ≥ 20 kg static, opens 100 mm thumb-to-index and closes in ≤ 0.65 s with 0.1° repeat accuracy. The Basic version talks RS485 and CAN FD on 12–28 V; Pro and Touch add EtherCAT, 12–64 V and tactile sensing. Python / C SDK for Linux, Windows and ROS.","schema_version":"3.0","revision":null,"tags":["end_effector","dexterous hand","robot hand","humanoid hand","brainco","revo 2","bionic hand","can fd robot hand","end effector","robotics"],"sources":[{"other":{},"id":"datasheet","url":"https://cdn.shopify.com/s/files/1/0673/6848/5000/files/BrainCo_Bionic_Dexterous_Hand_Revo_2-Product-Manual-V2.1EN.pdf","title":"BrainCo Revo 2 Dexterous Hand datasheet","publisher":"BrainCo","kind":"datasheet","retrieved_at":"2026-10-18T07:38:33+00:00","field_paths":["spec.constraints.thermal.operating_temp_max_c","spec.constraints.thermal.operating_temp_min_c","spec.geometry.cad.assumptions","spec.geometry.cad.bbox.height_mm","spec.geometry.cad.bbox.length_mm","spec.geometry.cad.bbox.width_mm","spec.geometry.cad.envelope_complete","spec.geometry.cad.mesh_path","spec.geometry.cad.step_path","spec.geometry.cad.verification","spec.geometry.dimensions.height_mm","spec.geometry.dimensions.length_mm","spec.geometry.dimensions.width_mm","spec.geometry.other.weight_g","spec.provides.actuator_included","spec.provides.control_interface","spec.provides.dof","spec.provides.drive","spec.provides.effector_type","spec.provides.features","spec.provides.grip_force_n","spec.provides.jaw_opening_max_mm","spec.provides.mount_pattern","spec.provides.payload_kg","spec.usage.connectors","spec.usage.pinout_complete"],"notes":"sha256 e2f4cae6fb8a339f12e5148a23bb2dcc798678956885f72cc32b8cba44e26575"},{"other":{},"id":"offer0","url":"https://aifitlab.com/products/brainco-bionic-dexterous-hand-revo-2?variant=44957840638088","title":"aifitlab.com listing","publisher":null,"kind":"distributor","retrieved_at":"2026-10-18T07:39:43+00:00","field_paths":["offers"],"notes":null}],"assets":[{"other":{},"kind":"datasheet","url":"https://cdn.shopify.com/s/files/1/0673/6848/5000/files/BrainCo_Bionic_Dexterous_Hand_Revo_2-Product-Manual-V2.1EN.pdf","label":"Datasheet","verification":"manufacturer","notes":null},{"other":{},"kind":"image","url":"https://cdn.shopify.com/s/files/1/0673/6848/5000/files/BrainCo_Bionic_Dexterous_Hand_Revo_2-main-1-1.jpg","label":"BrainCo Revo 2 — product photo (Flowing Silver)","verification":"unverified","notes":"inspected: BrainCo render, silver five-finger hand with dark thumb base and round wrist flange; distributor-hosted maker render"},{"other":{},"kind":"cad","url":"brainco-revo-2.step","label":"STEP (generated from datasheet drawing)","verification":"generated","notes":"cad_check passed"}],"offers":[{"other":{"price_breaks":[]},"supplier":"aifitlab.com","url":"https://aifitlab.com/products/brainco-bionic-dexterous-hand-revo-2?variant=44957840638088","currency":"USD","unit_price":5400,"stock_status":"preorder","region":"US","minimum_quantity":null,"checked_at":"2026-10-18T07:39:43+00:00","lead_time_days_min":null,"lead_time_days_max":null,"destination":"US","destination_postal_code":null,"notes":null,"price_basis":"listed","unit_price_max":null}],"best_for":[{"other":{},"label":"Humanoid and research robot hands","reason":"11-DoF hand (6 active) with ≥ 50 N grasp, 100 mm opening, 0.1° repeatability and an ROS SDK over RS485 / CAN FD — a light (383 g) hand for humanoid and manipulation research.","basis":"engineering_inference"}],"children":[],"spec":{"other":{},"usage":{"other":{},"pinout":[],"derived":{},"connectors":[{"id":"comm","kind":"RS485 + CAN FD (Basic); RS485 + CAN FD + EtherCAT (Pro / Touch)","other":{}}],"pin_mappings":[],"requirements":{"other":{},"data_inputs":[],"power_inputs":[]},"pinout_complete":false},"geometry":{"cad":{"bbox":{"width_mm":78.5,"height_mm":38,"length_mm":160},"features":[],"mesh_path":"brainco-revo-2.stl","step_path":"brainco-revo-2.step","assumptions":["height=38 mm assumed: no palm thickness printed; the Ø38 wrist is used for the CAD envelope only"],"verification":"generated","envelope_complete":false},"other":{"weight_g":383},"derived":{},"dimensions":{"other":{},"width_mm":78.5,"height_mm":38,"length_mm":160},"feature_boxes":[],"mounting_holes":[]},"provides":{"dof":11,"drive":"coreless motors (6)","other":{},"derived":{},"features":["Versions: Basic (XRL/XRR) 485 + CAN FD, 12–28 V; Pro (XEL/XER) adds EtherCAT, 12–64 V; Touch (XTL/XTR) adds multi-modal fingertip tactile sensing","Communication up to 1 kHz; Modbus-RTU / CAN FD protocols (EtherCAT on Pro / Touch)","Wrist interface: Ø38 × 13.5 mm, fixed with 4 × M3 screws around the circumference; Pro / Touch thread depth 3.5 mm (screw < 3 mm into the wrist)","Dimensions: hand length 160 mm, max palm width 78.5 mm, thumb length 92 mm, wrist height 13.5 mm, wrist Ø38 mm","Current (Basic, 24 V): 65 mA static, 350 mA average no-load, 4.6 A max","Control: position / velocity / current feedback, cascaded and compliance control; protection: over-current, stall, over-temperature, collision","Noise ≤ 50 dB at 50 cm; aerospace aluminium + food-grade plastic; OTA firmware updates","Availability (2026-10-18): AIFIT Lab Basic $5400 (left / right, silver / grey), Pro $6760; backordered"],"payload_kg":20,"capabilities":[],"grip_force_n":50,"effector_type":"dexterous_hand","mount_pattern":"wrist Ø38 mm, 4 × M3 screws around the circumference","actuator_included":"yes — six built-in coreless motors","control_interface":"RS485 + CAN FD (Basic)","jaw_opening_max_mm":100},"compliance":{"other":{},"derived":{},"certifications":[]},"constraints":{"other":{},"derived":{},"thermal":{"other":{},"operating_temp_max_c":40,"operating_temp_min_c":-10},"electrical":{"other":{}}}},"other":null,"source_type":"pdf","source_ref":"https://cdn.shopify.com/s/files/1/0673/6848/5000/files/BrainCo_Bionic_Dexterous_Hand_Revo_2-Product-Manual-V2.1EN.pdf","datasheet":{"cad":{"bbox":{"max":[160,78.5,38],"min":[0,0,0],"width_mm":78.5,"height_mm":38,"length_mm":160},"check":{"failed":[],"passed":true},"expected":[{"x":160,"y":78.5,"name":"envelope","what":"box_xy"},{"what":"envelope_z","value":38}],"archetype":"envelope_box","mesh_path":"/Users/sumeet/Documents/Xirkit Parent/XirkitOnboard/work/brainco-revo-2/07_cad/part.stl","step_path":"/Users/sumeet/Documents/Xirkit Parent/XirkitOnboard/work/brainco-revo-2/07_cad/part.step","views_png":"/Users/sumeet/Documents/Xirkit Parent/XirkitOnboard/work/brainco-revo-2/07_cad/views.png","export_stl":"brainco-revo-2.stl","assumptions":["height=38 mm assumed: no palm thickness printed; the Ø38 wrist is used for the CAD envelope only"],"export_step":"brainco-revo-2.step","source_step":null,"verification":"generated","envelope_complete":false},"chips":[],"fields":{"dof":{"src":{"page":5,"quote":"coreless-motors, 6 active joints, and 11 degrees of freedom (DoF). With a single-","method":"text"},"unit":null,"value":11},"drive":{"src":{"page":5,"quote":"coreless-motors, 6 active joints, and 11 degrees of freedom (DoF). With a single-","method":"text"},"unit":null,"value":"coreless motors (6)"},"weight":{"src":{"page":23,"quote":"| Weight | 383 g | 383 g | 383 g |","method":"table","table_id":"23_1"},"unit":"g","value":383},"payload":{"src":{"page":8,"quote":"Static Load ≥20kg","method":"text"},"orig":{"unit":"kg","value":20},"unit":"g","value":20000},"grip_force":{"src":{"page":8,"quote":"Power Grasp Force ≥50N","method":"text"},"unit":"N","value":50},"jaw_opening":{"src":{"page":23,"quote":"| Maximum opening and closing distance | 100mm(from thumb to index finger) | 100mm(from thumb to index finger) | 100mm(from thumb to index finger) |","method":"table","table_id":"23_1"},"unit":"mm","value":100},"effector_type":{"src":{"page":1,"quote":"Revo 2 BrainCo Dexterous Hand","method":"text"},"unit":null,"value":"dexterous_hand"},"mount_pattern":{"src":{"page":10,"quote":"The wrist interface is fixed circumferentially with 4 M3 screws.","method":"text"},"unit":null,"value":"wrist Ø38 mm, 4 × M3 screws around the circumference"},"rated_voltage":{"src":{"page":23,"quote":"| Supply voltage | 12-28V | 12-64V | 12-64V |","method":"table","table_id":"23_1"},"unit":"V","value":[12,28]},"actuator_included":{"src":{"page":5,"quote":"coreless-motors, 6 active joints, and 11 degrees of freedom (DoF). With a single-","method":"text"},"unit":null,"value":"yes — six built-in coreless motors"},"control_interface":{"src":{"page":9,"quote":"Revo 2 Basic Dexterous Hand supports two external communication","method":"text"},"unit":null,"value":"RS485 + CAN FD (Basic)"},"operating_temperature":{"src":{"page":23,"quote":"| Operating temperature | -10 - 40℃ / 90%RH | -10 - 40℃ / 90%RH | -10 - 40℃ / 90%RH |","method":"table","table_id":"23_1"},"unit":"°C","value":[-10,40]}},"groups":{"all":[]},"source":{"url":"https://cdn.shopify.com/s/files/1/0673/6848/5000/files/BrainCo_Bionic_Dexterous_Hand_Revo_2-Product-Manual-V2.1EN.pdf","pages":23,"sha256":"e2f4cae6fb8a339f12e5148a23bb2dcc798678956885f72cc32b8cba44e26575","onboarded_at":"2026-10-18T07:40:00+00:00"},"coverage":{"pct":100,"score":"20/20","passed":true,"explained_nulls":["height","compliance","lifecycle"]},"entities":[],"taxonomy":{"pinouts":{"role":"pins_or_terminals","definition":"Servo leads / connector wiring"},"dimensions":{"role":"mechanical_dimensions","definition":"Dimension drawing / spec sheet: overall size, jaw opening, mounting holes"},"site_chrome":{"role":"other","definition":"Navigation, related products, footers, page headers"},"specifications":{"role":"electrical_ratings","definition":"Specs: jaw opening / stroke, grip force, payload, weight, servo / actuator, voltage, mounting pattern"},"pricing_ordering":{"role":"ordering_commercial","definition":"Price, SKU / part number, stock"},"product_overview":{"role":"identity_overview","definition":"Overview: gripper type (parallel / angular), what drives it, what it mounts to, kit contents"}},"variants":{},"commercial":{"other":{},"checked_at":"2026-10-18T07:39:43+00:00","compliance":[],"ordering_codes":[{"code":"XRL","description":"Revo 2 Basic left (XRR = right)"}]},"mechanical":{"dims":{"width":{"src":{"page":7,"quote":"| 2 | Maximum Palm Width | 78.5mm |","method":"table","table_id":"7_1"},"note":"palm; thumb extends beyond","unit":"mm","value":78.5},"length":{"src":{"page":7,"quote":"| 1 | Hand Length (from middle fingertip to palm base) | 160mm |","method":"table","table_id":"7_1"},"unit":"mm","value":160}},"kind":"mechanical","holes":[],"units":"mm","origin":"hand envelope from (0,0,0); length along the middle finger","features":[],"archetype":"envelope_box","assumptions":{"height":{"why":"no palm thickness printed; the Ø38 wrist is used for the CAD envelope only","value":38}}},"page_index":[{"page":1,"tags":[],"primary":"none_of_these"},{"page":2,"tags":[],"primary":"none_of_these"},{"page":3,"tags":[],"primary":"none_of_these"},{"page":4,"tags":[],"primary":"none_of_these"},{"page":5,"tags":["product_overview"],"primary":"product_overview"},{"page":6,"tags":[],"primary":"none_of_these"},{"page":7,"tags":["dimensions"],"primary":"dimensions"},{"page":8,"tags":["specifications"],"primary":"specifications"},{"page":9,"tags":[],"primary":"none_of_these"},{"page":10,"tags":["dimensions"],"primary":"dimensions"},{"page":11,"tags":[],"primary":"none_of_these"},{"page":12,"tags":[],"primary":"none_of_these"},{"page":13,"tags":["specifications"],"primary":"specifications"},{"page":14,"tags":["product_overview"],"primary":"product_overview"},{"page":15,"tags":["product_overview"],"primary":"product_overview"},{"page":16,"tags":[],"primary":"none_of_these"},{"page":17,"tags":[],"primary":"none_of_these"},{"page":18,"tags":[],"primary":"none_of_these"},{"page":19,"tags":[],"primary":"none_of_these"},{"page":20,"tags":["pricing_ordering"],"primary":"pricing_ordering"},{"page":21,"tags":[],"primary":"none_of_these"},{"page":22,"tags":["product_overview"],"primary":"product_overview"},{"page":23,"tags":["specifications"],"primary":"specifications"}],"performance":[],"schema_name":"datasheet-1","part_ratings":{}},"use_cases":["grasping-manipulation"],"commercial":{"other":{},"checked_at":"2026-10-18T07:39:43+00:00","compliance":[],"ordering_codes":[{"code":"XRL","description":"Revo 2 Basic left (XRR = right)"}]},"null_reasons":{"height":{"note":"no palm thickness printed; CAD uses an explicit assumption","reason":"not_in_source"},"lifecycle":{"note":"store availability is not lifecycle evidence","reason":"not_in_source"},"compliance":{"note":"not stated","reason":"not_in_source"}},"assembly_label":"Mechanism","assembly_level":3,"search_aliases":["dexterous hand 100 mm","Revo 2 Basic (XRL / XRR)"],"design":{"assets":[{"other":{},"kind":"datasheet","url":"https://cdn.shopify.com/s/files/1/0673/6848/5000/files/BrainCo_Bionic_Dexterous_Hand_Revo_2-Product-Manual-V2.1EN.pdf","label":"Datasheet","verification":"manufacturer","notes":null,"resolved_url":"https://cdn.shopify.com/s/files/1/0673/6848/5000/files/BrainCo_Bionic_Dexterous_Hand_Revo_2-Product-Manual-V2.1EN.pdf"},{"other":{},"kind":"image","url":"https://cdn.shopify.com/s/files/1/0673/6848/5000/files/BrainCo_Bionic_Dexterous_Hand_Revo_2-main-1-1.jpg","label":"BrainCo Revo 2 — product photo (Flowing Silver)","verification":"unverified","notes":"inspected: BrainCo render, silver five-finger hand with dark thumb base and round wrist flange; distributor-hosted maker render","resolved_url":"https://cdn.shopify.com/s/files/1/0673/6848/5000/files/BrainCo_Bionic_Dexterous_Hand_Revo_2-main-1-1.jpg"},{"other":{},"kind":"cad","url":"brainco-revo-2.step","label":"STEP (generated from datasheet drawing)","verification":"generated","notes":"cad_check passed","resolved_url":"https://wlrumvsjnliyuuvzwnrt.supabase.co/storage/v1/object/public/geometry/brainco-revo-2.step"}],"cad":{"verification":"generated","envelope_complete":false,"assumptions":["height=38 mm assumed: no palm thickness printed; the Ø38 wrist is used for the CAD envelope only"],"step_path":"brainco-revo-2.step","mesh_path":"brainco-revo-2.stl","footprint_svg_path":null,"bbox":{"length_mm":160,"width_mm":78.5,"height_mm":38},"features":[],"step_url":"https://wlrumvsjnliyuuvzwnrt.supabase.co/storage/v1/object/public/geometry/brainco-revo-2.step","mesh_url":"https://wlrumvsjnliyuuvzwnrt.supabase.co/storage/v1/object/public/geometry/brainco-revo-2.stl","footprint_svg_url":null},"limitations":["Generated geometry is an approximate mechanical envelope; inspect original manufacturer CAD when available.","Generated footprint_svg_path is an outline, not a verified electrical land pattern.","Xirkit does not run fit checks; download step_url and test fit against your own enclosure."]}}}